Thermocouple type j and l are frequently used because of their high emf output and their low cost. They are mostly used for applications at temperatures above 550 c up to the maximum working pressure of the thermocouple. K type thermocouple extension wire omega engineering. Tolerance value of the accuracy classes 1 and 2 of thermocouple type k. Thermocouple grade 328 to 662f 200 to 350c extension grade 76 to 212f 60 to 100c limits of error whichever is greater standard. The to order box contains some examples of popular models. Overall, brown use the table below as a guide for types.
Reading colorcode abrasionresistance moistureresistance. Type k, like type e should not be used in sulfurous atmospheres, in a vacuum or in low oxygen environments where selective oxidation will occur. It is equivalent to the type k in terms of expense and reliability. Belden thermocouple extension wire type determines the conductor material. A leading manufacturer of quality thermocouple and rtd assemblies since 1972 thermocouple wire this section has been developed to serve as a guide in the selection of wires to accomplish most all temperature measuring requirements. Featured is a large selection of thermoelements, insulation materials and constructions. Thermocouple grade wire, 454 to 2,300f 270 to 1260c extension wire, 32 to 392f 0 to 200c type k accuracy whichever is greater. Thermocouple iron wire is supplied coppercoated to prevent oxidation. A basic guide to thermocouple measurements 1 thermocouple overview thermocouples are temperature measurement sensors that generate a voltage that changes over temperature. Thermocouples are a widely used type of temperature sensor commercial thermocouples are inexpensive, interchangeable. K type thermocouples are known as general purpose thermocouple due to its low cost and temperature range. The temperature range for type k is 330 to 2300 f and its wire color code is yellow and red. Options compatible with previous selections will be in bold.
Connect your devices to sensing or controlling equipment with belden thermocouple wire and extension grade cable. The type k is the most common type of thermocouple. Thermocouple extension cable type k,j,r,s,t,n,l,b sab kabel. Compared the resistance with known type k cables and it was way off so the material cant be correct. The best known and dominant thermocouple belonging to the group chromiumnickel aluminium is type k. Thermocouple types types of thermocouples comparison. It has integrated composition of chromel and alumel wires has a range of 270 c to. Type j thermocouple ironconstantan is also very common.
Power limited tray cable pltc os thermocouple cables are suitable for use in extension grade. This sensor consists of two dissimilar metal wires, joined at one end, and connected to a thermocouple thermometer or other thermocouple capable device at the other end. Fep insulation and jacket is abrasion and chemical resistant. Type k chromelalumel is the most common generalpurpose thermocouple with a sensitivity of approximately 41 vc. Cables made of original materials are called extension or thermocouple cables, whereas. Thermocouplesthermocouple types j, k, e, t, n, b, r, s. Number wire conductor overall c f mm inch kg lb 20 kkj20 solid fused polyimide tape 260500 1. Overall, brown weight of spool and wire rounded to the next highest kg lb does not include packing material. K type thermocouple extension wire exffk16100 exffk16100. A thermocouple is a type of temperature sensor, which is made by joining two. Ansi type j and k duplex thermocouple wire stocked on 100 and 250 foot spools.
Wasted time building thermocouple extension cables only to find out the wire is wrong. Type kx extension wire is suitable from 32 to 392f. Thermocouple wire types, construction and characteristics standard fiberglass insulations single conductor duplex conductor temp. Rating physical properties type insulation inches impregnation insulation inches impregnation continuous astmansi sgl. The type n thermocouple has a nicrosil nickel14% chromium 1. The type e thermocouple is a commonly used thermocouple which provides stronger signal and higher accuracy as compared to type k and type j at moderate temperature range of f and lower. Fiberglass insulation and jacket is rated for higher temperatures than fep and is highly chemical resistant. Thermocouple types types of thermocouples comparison of. Interchangeability tolerances are the same as for type k. Cuprothal can be used at temperatures down to 20 k where its seebeck coefficient is about 8. It is however very useful in food, environmental and refrigeration applications. For help selecting the best probe for your need, please contact our sales team.
Thermocouple type e has the highest emf output of any common thermocouple and is for this reason used in thermal generators thermopiles. Mineral insulated thermocouples type k, type j, mineral insulated. Ansi american national standards institute additional constructions available upon request. Thermo sensors thermocouple and extension wires are known for their. A thermocouple is a device made by two different wires joined at one end, called junction end or measuring end. Although thermocouple calibration dictates the temperature range, the maximum range is also limited by the the diameter of the thermocouple wire. Thermocouple reference tables thermocouple reference table. This information can usually be found on the face of the instrument.
Thermocouples are constructed from two wire leads made from different metals. Overall, brown omega engineering does not use reprocessed pfa or pvc in manufacturing thermocouple wire weight of spool and wire rounded to the next highest kg lb does not include packing material. The wire leads are welded together to create a junction. This type of thermocouple should only be used in oxidizing or inert atmospheres with a service temperature range between 200c and 1260c 330f to 2300f. A thermocouple is a sensor for measuring temperature. A nylon rip cord is included in all pvcjacketed thermocouple extension cables. The type k is commonly found in nuclear applications because of its relative radiation hardness. The type e has higher stability when compared to type k thermocouple due to which it provide good accuracy. Type k can be used in temperatures from 454 to 2300f.
Thermocouple material specifications gen6 269 the thermocouple element materials listed below are those most commonly found in process applications. Newnistpublication june12,1989 thecalibrationof thermocouplesand thermocouplematerials nist special publication 25035 g. It was developed to be more stable exhibit less calibration drift than type k when. Fiberglass insulated thermocouple wirefbfb specification. That is, a very thin thermocouple may not reach the full temperature range. Max6675 coldjunctioncompensated kthermocouple todigital. Thermocouple construction materials the most basic thermocouple construction is the wire type consisting of two dissimilar metals homogeneously joined at one end to form the measuring junction.
When properly configured, thermocouples can provide temperature measurements over wide range of temperatures. We differentiate between thermocouple cable and compensating cable. Type k and kx thermocouple wire are widely used and provide reliability, dependability, and precision at low cost. Its inexpensive, accurate, reliable, and has a wide temperature range. Select from general purpose probes, high temperature probes, penetration probes, surface probes, wire probes, and thermocouple accessories. All wire type thermocouples have an exposed junction. Thermocouple wire type k, duplex insulated xc k tc wire ansi color code k type thermocouple wire. When ordering replacement thermocouple wire or elements be certain that the type k, s, r, etc.
Thermoworks carries dozens of type k thermocouple probes. Type k thermocouple reference tables, type j reference tables, all major thermocouple reference tables reotemp instrument corporation 10656 roselle street san diego, ca 92121 phone. The 240page strategic report provides critical insights on the thermocouple wire market size, share, trend, forecasts, and opportunity analysis. Type k, type j, type e, type t, type r, type s, etc. Nanmac world leader in thermocouples, rtds, and calibration. Selection of the proper thermocouple type for a particular application is determined by temperature expectations and by the environment in which the sensor will be placed. A thermocouple produces a temperaturedependent voltage as a result of the thermoelectric effect, and this voltage can be interpreted to measure temperature. The other end of the thermocouple is called tail end or reference end figure1. Type k thermocouples should not be used in sulphuric environment since both elements will rapidly corrode and the negative element will eventually fail mechanically due to becoming brittle. Compensating cables of type kca are used together with thermocouples of type k. The calibration of thermocouples and thermocouple materials. Type k thermocouple reference tables celsius type k thermocouple reference tables celsius reference n.
Its90 table for type k thermocouple ref junction thermoelectric voltage in mv o 017 718 1. All omega thermocouple wire, probes and connectors are available with. The temperature range, emf output, accuracy required, resistance to atmospheric conditions, pressure and shock are typical thermocouple systems for a given application. Overall, brown use the table below as a guide for types available. The best known and dominant thermocouple belonging. Thermocouple wire duplex insulated omega engineering. Calibration awg model type insulation maximum temperature nominal size wt. The temperature ranges for type e, j, k and t thermocouple wires listed above pertain to 20 awg wire. Consideration for bare wire type j thermocouple applications. Thermocouple and rtd wire and cable wire and cable. The two wires are called thermoelements or legs of the thermocouple. It has a smaller temperature range and a shorter lifespan at higher temperatures than the type k. A thermocouple is an electrical device consisting of two dissimilar electrical conductors forming an electrical junction. Selection of the optimum type of thermocouple and auxiliary components for a pyrometric system is necessarily based on a number of variables or factors of the application.
471 776 241 1034 596 874 1133 1413 278 384 403 421 139 883 1159 1613 1029 453 503 499 943 317 1190 1042 182 171 229 1399 725 552